459
Global
Height rank
Corporate Avenue 2
Chongqing China
Height

Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

1
To Tip:

Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest point of the building, irrespective of material or function of the highest element (i.e., including antennae, flagpoles, signage and other functional-technical equipment).

255.8 m / 839 ft
2
Architectural:

Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

255.8 m / 839 ft
Floors

The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

Above Ground

The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

47
Below Ground

The number of floors below ground should include all major floors located below the ground floor level.

4
1 2 Corporate Avenue 2 Outline
Height 255.8 m / 839 ft
Floors 47
Official Name

The current legal building name.

Corporate Avenue 2
Other Names

Other names the building has commonly been known as, including former names, common informal names, local names, etc.

Chongqing International Trade and Commerce Center 2, Chongqing Corporate Avenue 2, Jia Ling Fan Ying International Trade & Commerce Centre 2
Name of Complex

A complex is a group of buildings which are designed and built as pieces of a greater development.

Type

CTBUH collects data on two major types of tall structures: 'Buildings' and 'Telecommunications / Observation Towers.' A 'Building' is a structure where at least 50% of the height is occupied by usable floor area. A 'Telecommunications / Observation Tower' is a structure where less than 50% of the structure's height is occupied by usable floor area. Only 'Buildings' are eligible for the CTBUH 'Tallest Buildings' lists.

Building
Status
Completed
Architecturally Topped Out
Structurally Topped Out
Under Construction
Proposed
On Hold
Never Completed
Vision
Competition Entry
Canceled
Proposed Renovation
Under Renovation
Renovated
Under Demolition
Demolished
Completed, 2014
Country

The CTBUH follows the United Nations's definition of Country, and thus uses the lists and codes established by that organization.

City

The CTBUH follows the United Nations's definition of City, and thus uses the lists and codes established by that organization.

Function

A single-function tall building is defined as one where 85% or more of its usable floor area is dedicated to a single usage. Thus a building with 90% office floor area would be said to be an "office" building, irrespective of other minor functions it may also contain.

A mixed-use tall building contains two or more functions (or uses), where each of the functions occupy a significant proportion of the tower's total space. Support areas such as car parks and mechanical plant space do not constitute mixed-use functions. Functions are denoted on CTBUH "Tallest Building" lists in descending order, e.g., "hotel/office" indicates hotel function above office function.

office
Structural Material

Steel
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from steel. Note that a building of steel construction with a floor system of concrete planks or concrete slab on top of steel beams is still considered a “steel” structure as the concrete elements are not acting as the primary structure.

Reinforced Concrete
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from concrete which has been cast in place and utilizes steel reinforcement bars.

Precast Concrete
Both the main vertical/lateral structural elements and the floor spanning system are constructed from steel reinforced concrete which has been precast as individual components and assembled together on-site.

Mixed-Structure
Utilizes distinct systems (e.g. steel, concrete, timber), one on top of the other. For example, a steel/concrete indicates a steel structural system located on top of a concrete structural system, with the opposite true of concrete/steel.

Composite
A combination of materials (e.g. steel, concrete, timber) are used together in the main structural elements. Examples include buildings which utilize: steel columns with a floor system of reinforced concrete beams; a steel frame system with a concrete core; concrete-encased steel columns; concrete-filled steel tubes; etc. Where known, the CTBUH database breaks out the materials used in a composite building’s core, columns, and floor spanning separately.

composite
Core
Reinforced Concrete
Columns
Concrete Filled Steel
Floor Spanning
Steel
LEED Gold BD+C: Core and Shell
Official Website
Height

Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

Architectural
255.8 m / 839 ft
To Tip
255.8 m / 839 ft
Floors Above Ground

The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

47
Floors Below Ground

The number of floors below ground should include all major floors located below the ground floor level.

4
# of Parking Spaces

Number of Parking Spaces refers to the total number of car parking spaces contained within a particular building.

815
# of Elevators

Number of Elevators refers to the total number of elevator cars (not shafts) contained within a particular building (including public, private and freight elevators).

25
Tower GFA

Tower GFA refers to the total gross floor area within the tower footprint, not including adjoining podiums, connected buildings or other towers within the development.

116,000 m² / 1,248,614 ft²
Rankings
#
459
Tallest in the World
#
279
Tallest in Asia
#
13
Tallest in Chongqing
#
193
Tallest Office Building in the World
#
125
Tallest Office Building in Asia
#
106
Tallest Office Building in China
#
4
Tallest Office Building in Chongqing
#
216
Tallest Composite Building in the World
#
181
Tallest Composite Building in Asia
#
166
Tallest Composite Building in China
#
6
Tallest Composite Building in Chongqing
Construction Schedule
2007

Proposed

2010

Construction Start

2014

Completed

Owner/Developer
Architect
Chongqing Architecture and Design Institute; Kohn Pedersen Fox Associates
Structural Engineer
MEP Engineer
China Construction Third Engineering Bureau Co., Ltd.

Fire

Geotechnical

Landscape

Design Land Collaborative

Sustainability

Wind

BMT Fluid Mechanics Ltd.; Cermak Peterka Petersen (CPP), Inc.

Cladding

ALT Limited; Jangho Group Co., Ltd.

Elevator

CTBUH Initiatives

31 December 2014 - CTBUH Journal

Research

31 December 2014

Daniel Safarik, Antony Wood, Marty Carver & Marshall Gerometta, CTBUH

An All-Time Record 97 Buildings of 200 Meters or Higher Completed in 2014 and 2014 showed further shifts towards Asia, and also surprising developments in...

31 December 2014

Daniel Safarik, Antony Wood, Marty Carver & Marshall Gerometta, CTBUH

An All-Time Record 97 Buildings of 200 Meters or Higher Completed in 2014 and 2014 showed further shifts towards Asia, and also surprising developments in...

31 December 2014

An All-Time Record 97 Buildings of 200 Meters or Higher Completed in 2014 and 2014 showed further shifts towards Asia, and also surprising developments in building functions and structural materials.